CMS 139v11: Falls: Screening for Future Fall Risk
Measure: Percentage of patients 65 years of age and older who were screened for future fall risk during the measurement period | ||
Measure Type | High Priority Measure | Scoring |
Process | Yes | A higher percentage indicates better quality |
Denominator | Patients aged 65 years and older at the start of the measurement period with a visit during the measurement period |
Numerator | Patients who were screened for future fall risk at least once within the measurement period |
Denominator Exceptions | None |
Denominator Exclusions | Patients who are in hospice care for any part of the measurement period |
Patients who meet the following criteria will be included in the denominator:
-
Age is ≥ 65 years at the beginning of the Measurement Period
AND
- Have at least one eligible encounter during the Measurement Period finalized by the EC
CPT: 99201, 99202, 99203, 99204, 99205, 99212, 99213, 99214, 99215, 99395, 99396, 99397, 99385, 99386, 99387, 99341, 99342, 99343, 99344, 99345, 99347, 99348, 99349, 99350, 92002, 92004, 92012, 92014, 99401, 99402, 99403, 99404, 99315, 99316, 99318, 99304, 99305, 99306, 99307, 99308, 99309, 99310, 99324, 99325, 99326, 99327, 99328, 99334, 99335, 99336, 99337, 92540, 92541, 92542, 92548, 98969, 98970, 98971, 98972, 99421, 99422, 99423, 99458, 97161, 97162, 97163, 97164, 97165, 97166, 97167, 97168
HCPCS: G0438, G0439, G0071, G2010, G2012, G2061, G2062, G2063
Patients who were in hospice care during any part of the Measurement Period will be excluded from the measure.
To document hospice care ambulatory services, go to Encounter > Orders/Procedure > Orders/Referrals and click Add to add one of the eligible codes listed below:
CPT: 99377, 99378
HCPCS: G0182
Order Status must be marked as Pending or Complete.
To document hospice care encounter services, go to Encounter > Orders/Procedure > Orders/Referrals and click Add to add one of the eligible codes listed below:
HCPCS: G9996, G9473, G9474, G9475, G9476, G9477, G9478, G9479, Q5003, Q5004, Q5005, Q5006, Q5007, Q5008, Q5010, S9126, T2042, T2043, T2044, T2045, T2046
Order Status must be marked as Complete.
A patient will be counted in the numerator if they received a fall risk screening using the Morse Fall Scale assessment tool or through another screening method during the Measurement Period.
To document the performance of a fall risk screening with a different screening tool:
- Go to Encounter > Flowsheets/Labs > Standard or Chart > Flowsheets/Labs > Standard
- Click Add New Flowsheet
- Select the Fall Risk Screening flowsheet and click Add
- Click Add Column
- Select the Done checkbox for Other fall risk assessment performed
- Click OK to save
If Other fall risk assessment performed is selected, the name of the screening tool should be documented in the encounter in which it was performed
Return to 2023 eCQMs
Didn't find the answer you were looking for?